HY series intelligent combined low voltage power capacitor

Short Description:

1. Applied to 0.4kV low voltage distribution network

2. Function:Reduce line loss, improve power factor and power quality

3. Integrated with modern measurement and control, power electronics,network communication,automation control,power capacitor

4. Compensation method: split phase (HYBAFB), three phase(HYBAGB) and mixed compensation(GB-H)

5. Protective function: Over-voltage protection, under-voltage protection,short-circuit protection, over-current protection, over-harmonic protection,over-temperature protection drive failure protection


Product Detail

Product Tags

Overview

Hengyi intelligent combined low voltage power capacitor compensation device (intelligent power capacitor) is an intelligent reactive power compensation device applied to 0.4kV low voltage distribution network to reduce line loss, improve power factor and power quality.

Integrated with modern measurement and control, power electronics, network communication, automation control, power capacitor and other advanced technologies. It has the characteristics of better compensation effect, smaller volume, lower power consumption, more cost-saving, more flexible application, easy maintenance, long span life, to meet the higher requirements of the modern power grid for reactive power compensation.

Model and Meaning

HY B A - □□ - □□ / / ( + )
| | | | | | | | |
1 2 3 4 6 7 8 9

No.

Name Meaning

1

Enterprise code HY

2

Design No. B

3

Automatic control A

4

Compensation method FB: split phase compensation GB: three phase compensation GB-H: mixed compensation

5

Procedure category  

6

Capacitor rated voltage three phase compensation: 450V、split phase compensation: 250V

7

Rated capacity  

8

First capacitor capacity  

9

Second capacitor capacity  

Technical Parameters

Normal working and installation conditions

Ambient temperature -25°C ~ +55°C
Relative humidity

Relative humidity < 50% at 40°C ; < 90% at 20°C

Altitude ≤ 2000m
Environmental conditions

no harmful gas and steam, no conductive or explosive dust, no severe mechanical vibration

Power condition  
Rated voltage

380V±20%

Rated frequency

50Hz (45Hz ~ 55Hz)

THDv

THDv ≤ 5%

THDi

THDi  ≤ 20%

Performance

Measurement tolerance Voltage: ≤ ±0.5%(0.8~1.2Un), current: ≤ ±0.5%(0.2~1.2ln), active power: ≤ ±2%, power factor: ≤ ±1 %, temperature:±1°C
Protection tolerance Voltage: ≤±1%Z current: ≤±1%,temperature:±1°C
Reactive compensation parameters Reactive power compensation tolerance: ≤ 50% of the min. capacitor capacity, capacitor switching time: ≥ 10s,can be set between 10s and 180s
Reliability parameter

Control accuracy: 100%, allowable switching times: 1 million times, capacitor capacity running time attenuation rate: ≤ 1% / year, capacitor capacity switching attenuation rate: ≤ 0.1% / 10,000 times

Protective function

Over-voltage protection, under-voltage protection, short-circuit protection, over-current protection, over-harmonic protection, over-temperature protection, drive failure protection

Standard

GB/T15576-2008

Communication monitoring capability
Communication interface RS485
Communication protocol

Modbus / DL645 protocol

Specifications and Data Sheets

Breaking capacity 6kA, 15kA main product specifications and data sheets

Compensation method  Specification Capacitor rated voltage(V) Rated capacity (kvar) dimension (WxDxH)mm Mounting dimension (W,xD,)mm
three phase compensation HYBAGB- □ □ /450/10(5+5) 450 10 80x395x215 50x375
HYBAGB- □ □ /450/15(10+5) 450 15 80x395x235 50x375
HYBAGB- □ □ /450/20(10+10) 450 20 80x395x235 50x375
HYBAGB- □ □ 450/30(15+15) 450 30 80x395x315 50x375
HYBAGB- □ □ /450/30(20+10) 450 30 80x395x315 50x375
HYBAGB- □ □ /450/40(20+20) 450 40 80x395x315 50x375
HYBAGB- □ □ /450/50(25+25) ☆ 450 50 80x395x345 50x375
HYBAGB- □ □ /450/60(30+30) ☆ 450 60 80x395x345 50x375
split phase compensation HYBAFB- □ □ /250/5 250 5 80x395x215 50x375
HYBAFB- □ □ /250/10 250 10 80x395x215 50x375
HYBAFB- □ □ /250/15 250 15 80x395x235 50x375
HYBAFB- □ □ /250/20 250 20 80x395x265 50x375
HYBAFB- □ □ /250/25 250 25 80x395x315 50x375
HYBAFB- □ □ /250/30 250 30 80x395x315 50x375
mixed compensation HYBAGB-H- □ □ /450/5+250/5 450/250 △ 5 + YN 5 86x395x248 50x375
HYBAGB-H- □ □ /450/10+250/5 450/250 △ 10 +YN 5 86x395x278 50x375
HYBAGB-H- □ □ /450/10+250/10 450/250 △ 10 +YN 10 86x395x278 50x375
HYBAGB-H- □ □ /450/15+250/15 450/250 △ 15 + YN 15 86x395x358 50x375
HYBAGB-H- □ □ /450/20+250/20 ☆ 450/250 △ 20 + YN 20 86x395x358 50x375
HYBAGB-H- □ □ /450/25+250/25 ☆ 450/250 △ 25+ YN 25 86x395x438 50x375
HYBAGB-H- □ □ /450/30+250/30 ☆ 450/250 △ 30 + YN 30 86x395x438 50x375
 

Ex: HYBAGB-/ 450/10 (5 + 5),-means program category.

Mixed compensation HYBAGB-H series, when equipped with controller , can be only used JKGHY-controller.

* Note: Breaking capacity 6kA

啊啊

Compensation method Specification Capacitor rated voltage(V) Rated capacity(kvar) dimension (WxDxH)mm Mounting
dimension
(W.xD,)mm
three phase compensation HYBAGB-35H □ □ /450/30(20+10) 450

30

85x390x350

50x375

HYBAGB-35H □ □ 7450/40(20+20) 450

40

85x390x350

50x375

HYBAGB-35H □ □ 7450/50(30+20) 450

50

103x398x365

70x375

HYBAGB-35H □ □ 7450/60(30+30) 450

60

103x398x365

70x375

HYBAGB-35H □ □ 7450/60(40+20) 450

60

103x398x365

70x375

HYBAGB-35H □ □ 7450/70(40+30) 450

70

103x398x405

70x375

split phase compensation HYBAFB-35H □ □ /250/10 250

10

85x390x250

50x375

HYBAFB-35H □ □ /250/20 250

20

85x390x300

50x375

HYBAFB-35H □ □ /250/30 250

30

85x390x350

50x375

HYBAFB-35H □ □ /250/10+5 250

15

103x398x305

70x375

HYBAFB-35H □ □ /250/10+10 250

20

103x398x305

70x375

HYBAFB-35H □ □ /250/20+10 250

30

103x398x365

70x375

HYBAFB-35H □ □ /250/20+20 250

40

103x398x365

70x375

  * Note:Split phase compensation series (built-in 2 sets of capacitors), when equipped with controller, can be only usedJKGHY-Z controller 

Accessories (Additional Purchased)

08131243

three phase compens ation type Secondary current transformer

Secondary current transformer

Name type Corresponding selection
Secondary current
transformer
three phase compensation Three phase compensation capacitor as
master
split phase (mixed) compensation type Split phase compensation capacitor as
master
08131243

split phase (mixed) compensation type Secondary current transformer

Communication cable

Specification length picture usage
W20 20cm 2122_01 Connection of two adjacent intelligent capacitors
 W80 80cm 2122_02 Connection of upper and lower layers of intelligent capacitors
 W260 260cm  2122_03 Connection of intelligent capacitors in main and sub cabinet
D300-W  300cm  2122_04 Connection of intelligent capacitor and controller

Functional Equivalence Diagram

212

Ordering Instruction(s)

rated voltage, rated capacity, three phase compensation /split phase compensation, application and other parameters need to be provided.

For example: HYBAGB- / 450/30 (20+ 10) 200 units

HYBAGB series, Capacitor rated voltage: 450V, rated capacity: 30kvar, quantity: 200 units


  • Previous:
  • Next:

  • Write your message here and send it to us