Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs for Power Capacitor 3 Phase, Power Filter Capacitor, Installing Capacitor, Many years of work experience, we have realized the importance of providing good quality products and the best before-sales and after-sales services.
Power Quality Cabinet – HYSPC three-phase load imbalance automatic adjustment device – LASTONE Detail:
Overview
Three-phase imbalances are common in low voltage distribution networks. Due to the existence of a large number of singlephase loads in urban and rural networks, the current imbalance between the three phases is particularly serious.
The current imbalance in the power grid will increase the loss of the line and transformer, reduce the output of the transformer, affect the operation safety of the transformer, and cause zero drift, resulting in three-phase voltage imbalance, and reduce the quality of power supply. In view of the above situation, our company have developed three-phase unbalanced automatic regulation device for the purpose of optimizing power quality and realizing energy conservation and emission reduction.
The device filters over 90% of the zero sequence current and controls the three-phase imbalance within 10% of the rated capacity.
Model and Meaning
| HY |
SPC |
- |
 |
- |
 |
/ |
 |
|
 |
|
 |
|
| │ |
│ |
|
│ |
|
│ |
|
│ |
|
│ |
|
│ |
|
| 1 |
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
| No. |
Name |
Meaning |
| 1 |
Enterprise code |
HY |
| 2 |
Product type |
three phase imbalanced regulation |
| 3 |
Capacity |
35kvar、70kvar、100kvar |
| 4 |
Voltage level |
400V |
| 5 |
Wiring Type |
4L: 3P4W 3L: 3P3W |
| 6 |
Mounting type |
outdoor |
| 7 |
Door opening mode |
No marked: the default is front door opening, wall mounted installation; Side door opening, plug-in three-phase four wire installation must be specified |
* Note: The parameters and dimensions of HYSPC module and HYSVG module on page 25 are the same
Technical Parameters
| Normal working and installation conditions |
|
| Ambient temperature |
-10℃ ~ +40℃ |
| Relative humidity |
5%~ 95%,no condensation |
| Altitude |
≤ 1500m,1500~3000m (derating 1% per 100m) according to GB / T3859.2 |
| Environmental conditions |
no harmful gas and steam, no conductive or explosive dust, no severe mechanical vibration |
| Outdoor installation |
At least 15cm space should be reserved for the upper and lower air outlets of the module, and at least 60cmspace should be reserved for the front and rear of the cabinet for easy maintenance. |
| Relative humidity |
Relative humidity:When the temperature is + 25 ℃ , the relative humidity can reach 100% in a short time |
| System parameters |
|
| Rated input line voltage |
380V (-20% ~ +20%) |
| Rated frequency |
50Hz ( 45Hz ~ 55Hz) |
| Power grid structure |
3P3W/3P4W (400V) |
| Current transformer |
100/5 ~ 5,000/5 |
| Circuit topology |
three-level |
| Overall eifficiency |
≥ 97% |
| Standard |
CQC1311-2017、DL/T1216-2013、JB/T11067-2011 |
| Performance |
| Three-phase balance compensation capability |
Imbalance < 3% |
| Target power factor |
1, Response time < 10ms |
| Reactive power compensation rate |
> 99% |
| Protective function |
Over-voltage protection, under-voltage protection, short-circuit protection, over-current protection, overtemperature protection, drive fault protection,lightning protection |
| Power distribution function |
With C-level lightning protection function |
| Communication monitoring capability |
| Display content |
Real-time operating information such as voltage, current, power factor, and operating temperature |
| Communication interface |
Standard RS485 interface, optional wifi or GPRS, (only one communication mode can be selected for the same device) |
| Communication protocol |
Modbus protocol |
| Mechanical properties |
| Mounting type |
F or H pole, installation inclination < 5 ℃ |
| IP grade |
IP grade |
| Dimension and structure |
capacity(kavr) |
front door opening |
side door opening |
weight(kg) |
holedimension |
| Dimension(W×H×D) |
mountingdimension(W×D) |
Dimension(W×H×D) |
mountingdimension (W×D) |
 |
35 |
760×1150×470 |
624×250 |
780×1110×620 |
644×350 |
50 |
4-Φ13 |
| 70 |
760×1150×470 |
624×250 |
780×1110×620 |
644×350 |
75 |
4-Φ13 |
| 100 |
760×1150×470 |
624×250 |
780×1110×620 |
644×350 |
95 |
4-Φ13 |
Product detail pictures:
Related Product Guide:
We thinks what buyers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better high-quality, reduced processing costs, charges are more reasonable, won the new and outdated consumers the support and affirmation for Power Quality Cabinet – HYSPC three-phase load imbalance automatic adjustment device – LASTONE , The product will supply to all over the world, such as: Slovenia, Curacao, Tunisia, we're now looking forward to even greater cooperation with overseas customers based on mutual benefits. We are going to work wholeheartedly to improve our products and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.