Our enhancement depends around the sophisticated devices ,exceptional talents and repeatedly strengthened technology forces for Air Compressor Capacitor, Apf Active Power Filter Supplies, Harmonic Filter, Our team members are aim to provides products with high performance cost ratio to our customers, and the goal for all of us is to satisfy our consumers from all over the world.
China Wholesale Reactive Power Compensation Quotes - Three phase series filter reactor – LASTONE Detail:
Overview
CKSG series three phase series filter reactors are often affected by harmonic current, switching inrush current and operating overvoltage when compensating capacitive reactive power, which will cause capacitor damage and power factor reduction. Install three phase filter reactors to suppress and absorb harmonics, protect capacitors, avoid the effects of harmonic voltage current and impulse voltage current, improve power quality, increase system power factor, and extend capacitor life
Standard:
● GB/T 1094.6-2011
● GB/T 19212.1-2016
Features
● Designed with secondary thermal sensitive temperature protection switch
● Full vacuum dipping process, low noise during operation
● Winding frame is reinforced environmental protection flame retardant plastic
Model and Meaning
| CKSG |
- 
|
-
|
-7%
|
P |
K |
| │ |
│ |
│ |
│ |
│ |
│ |
| 1 |
2 |
3 |
4 |
5 |
6 |
| No. |
Name |
Meaning |
| 1 |
Series code |
Dry air-cooled three phase series filter reactor CKDG: single phase |
| 2 |
Matching Capacitor rated voltage (kV) |
|
| 3 |
Rated capacity of matched capacitor (kvar) |
|
| 4 |
Rated reactance rate XL / Xc (%) |
△ :three phase compensation; Y:split phase compensation |
| 5 |
P: terminal block |
RS485 |
| 6 |
K: with temperature protection switch |
No mark: without temperature protection switch |
Technical Parameters
Normal working and installation conditions
| Ambient temperature |
-25°C~+50°C |
| Relative humidity |
Relative humidity ≤ 50% at 40°C ; ≤ 90% at 20°C |
| Altitude |
≤ 1000m |
| Performance |
|
| Rated voltage of capacitor |
0.4 kV、0.45 kV、0.48 kV、0.525 kV、0.66kV、0.69 kV; |
| Reactance ratio |
Reactance rate 4.5%, 5%, 6%, 7% is used to limit switching inrush current and suppress 5th and above harmonics
|
| Reactance ratio |
Reactance rate 12%, 14%, used to limit closing switching current and suppress 3rd and above harmonics
|
| Withstand voltage level 3.5kV / min |
5kV/min |
| Insulation class |
B, F, H; Noise ≤ 45dBz continuous operation under overload capacity ≤ 1.35ln |
| Dimension and structure |
Product category |
Specification |
Dimension WxDx H(mm) |
Mounting dimensiWxD(mm) |
 |
CKSG 7% copper wire |
5~10 kvar |
210x145x170 |
110×85
|
| 15-25 kvar |
210x155x175 |
110×85
|
| 30-50 kvar |
240x160x215 |
135×110
|
| CKSG 7% Aluminum wire |
5~8 kvar |
210x150x170 |
110×85
|
|
10-15 kvar
|
210x150x170 |
110×85
|
|
20-25 kvar
|
240x155x195 |
135×110
|
|
30-35 kvar
|
240x155x215 |
135×110
|
|
40-50 kvar
|
262x180x215 |
150×110
|
| CKSG 14% copper wire |
25-30 kvar
|
240x160x200 |
135×110
|
| CKSG 14% Aluminum wire |
25-30 kvar
|
270x190x215 |
150×120
|
| CKSG 14% copper wire. Aluminum wire |
40-50 kvar
|
290x190x240 |
180×120
|
Product detail pictures:
Related Product Guide:
We insist on offering good quality generation with very good business enterprise concept, honest income as well as best and fast assistance. it will bring you not only the premium quality product or service and huge profit, but probably the most significant is usually to occupy the endless market for China Wholesale Reactive Power Compensation Quotes - Three phase series filter reactor – LASTONE , The product will supply to all over the world, such as: Cairo, Swansea, Uruguay, In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which will be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we will continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.