Hengyi intelligent combined low voltage power capacitor compensation device (intelligent power capacitor) is an intelligent reactive power compensation device applied to 0.4kV low voltage distribution network to reduce line loss, improve power factor and power quality.
Integrated with modern measurement and control, power electronics, network communication, automation control, power capacitor and other advanced technologies. It has the characteristics of better compensation effect, smaller volume, lower power consumption, more cost-saving, more flexible application, easy maintenance, long span life, to meet the higher requirements of the modern power grid for reactive power compensation.
HY | B | A | - | □□ | - | □□ | / | □ | / | □ | ( | □ | + | □ | ) |
| | | | | | | | | | | | | | | | | | |||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
No. |
Name | Meaning | |||||||||||
1 |
Enterprise code | HY | |||||||||||
2 |
Design No. | B | |||||||||||
3 |
Automatic control | A | |||||||||||
4 |
Compensation method | FB: split phase compensation GB: three phase compensation GB-H: mixed compensation | |||||||||||
5 |
Procedure category | ||||||||||||
6 |
Capacitor rated voltage | three phase compensation: 450V、split phase compensation: 250V | |||||||||||
7 |
Rated capacity | ||||||||||||
8 |
First capacitor capacity | ||||||||||||
9 |
Second capacitor capacity |
Normal working and installation conditions
Ambient temperature | -25°C ~ +55°C |
Relative humidity |
Relative humidity < 50% at 40°C ; < 90% at 20°C |
Altitude | ≤ 2000m |
Environmental conditions |
no harmful gas and steam, no conductive or explosive dust, no severe mechanical vibration |
Power condition | |
Rated voltage |
380V±20% |
Rated frequency |
50Hz (45Hz ~ 55Hz) |
THDv |
THDv ≤ 5% |
THDi |
THDi ≤ 20% |
Performance
Measurement tolerance | Voltage: ≤ ±0.5%(0.8~1.2Un), current: ≤ ±0.5%(0.2~1.2ln), active power: ≤ ±2%, power factor: ≤ ±1 %, temperature:±1°C |
Protection tolerance | Voltage: ≤±1%Z current: ≤±1%,temperature:±1°C |
Reactive compensation parameters | Reactive power compensation tolerance: ≤ 50% of the min. capacitor capacity, capacitor switching time: ≥ 10s,can be set between 10s and 180s |
Reliability parameter |
Control accuracy: 100%, allowable switching times: 1 million times, capacitor capacity running time attenuation rate: ≤ 1% / year, capacitor capacity switching attenuation rate: ≤ 0.1% / 10,000 times |
Protective function |
Over-voltage protection, under-voltage protection, short-circuit protection, over-current protection, over-harmonic protection, over-temperature protection, drive failure protection |
Standard |
GB/T15576-2008 |
Communication monitoring capability | |
Communication interface | RS485 |
Communication protocol |
Modbus / DL645 protocol |
Breaking capacity 6kA, 15kA main product specifications and data sheets
Compensation method | Specification | Capacitor rated voltage(V) | Rated capacity (kvar) | dimension (WxDxH)mm | Mounting dimension (W,xD,)mm |
three phase compensation | HYBAGB- □ □ /450/10(5+5) | 450 | 10 | 80x395x215 | 50×375 |
HYBAGB- □ □ /450/15(10+5) | 450 | 15 | 80x395x235 | 50×375 | |
HYBAGB- □ □ /450/20(10+10) | 450 | 20 | 80x395x235 | 50×375 | |
HYBAGB- □ □ 450/30(15+15) | 450 | 30 | 80x395x315 | 50×375 | |
HYBAGB- □ □ /450/30(20+10) | 450 | 30 | 80x395x315 | 50×375 | |
HYBAGB- □ □ /450/40(20+20) | 450 | 40 | 80x395x315 | 50×375 | |
HYBAGB- □ □ /450/50(25+25) ☆ | 450 | 50 | 80x395x345 | 50×375 | |
HYBAGB- □ □ /450/60(30+30) ☆ | 450 | 60 | 80x395x345 | 50×375 | |
split phase compensation | HYBAFB- □ □ /250/5 | 250 | 5 | 80x395x215 | 50×375 |
HYBAFB- □ □ /250/10 | 250 | 10 | 80x395x215 | 50×375 | |
HYBAFB- □ □ /250/15 | 250 | 15 | 80x395x235 | 50×375 | |
HYBAFB- □ □ /250/20 | 250 | 20 | 80x395x265 | 50×375 | |
HYBAFB- □ □ /250/25 | 250 | 25 | 80x395x315 | 50×375 | |
HYBAFB- □ □ /250/30 | 250 | 30 | 80x395x315 | 50×375 | |
mixed compensation | HYBAGB-H- □ □ /450/5+250/5 | 450/250 | △ 5 + YN 5 | 86x395x248 | 50×375 |
HYBAGB-H- □ □ /450/10+250/5 | 450/250 | △ 10 +YN 5 | 86x395x278 | 50×375 | |
HYBAGB-H- □ □ /450/10+250/10 | 450/250 | △ 10 +YN 10 | 86x395x278 | 50×375 | |
HYBAGB-H- □ □ /450/15+250/15 | 450/250 | △ 15 + YN 15 | 86x395x358 | 50×375 | |
HYBAGB-H- □ □ /450/20+250/20 ☆ | 450/250 | △ 20 + YN 20 | 86x395x358 | 50×375 | |
HYBAGB-H- □ □ /450/25+250/25 ☆ | 450/250 | △ 25+ YN 25 | 86x395x438 | 50×375 | |
HYBAGB-H- □ □ /450/30+250/30 ☆ | 450/250 | △ 30 + YN 30 | 86x395x438 | 50×375 |
Ex: HYBAGB-/ 450/10 (5 + 5),-means program category. Mixed compensation HYBAGB-H series, when equipped with controller , can be only used JKGHY-controller. * Note: Breaking capacity 6kA |
Compensation method | Specification | Capacitor rated voltage(V) | Rated capacity(kvar) | dimension (WxDxH)mm | Mounting dimension (W.xD,)mm |
three phase compensation | HYBAGB-35H □ □ /450/30(20+10) | 450 |
30 |
85x390x350 |
50×375 |
HYBAGB-35H □ □ 7450/40(20+20) | 450 |
40 |
85x390x350 |
50×375 |
|
HYBAGB-35H □ □ 7450/50(30+20) | 450 |
50 |
103x398x365 |
70×375 |
|
HYBAGB-35H □ □ 7450/60(30+30) | 450 |
60 |
103x398x365 |
70×375 |
|
HYBAGB-35H □ □ 7450/60(40+20) | 450 |
60 |
103x398x365 |
70×375 |
|
HYBAGB-35H □ □ 7450/70(40+30) | 450 |
70 |
103x398x405 |
70×375 |
|
split phase compensation | HYBAFB-35H □ □ /250/10 | 250 |
10 |
85x390x250 |
50×375 |
HYBAFB-35H □ □ /250/20 | 250 |
20 |
85x390x300 |
50×375 |
|
HYBAFB-35H □ □ /250/30 | 250 |
30 |
85x390x350 |
50×375 |
|
HYBAFB-35H □ □ /250/10+5 | 250 |
15 |
103x398x305 |
70×375 |
|
HYBAFB-35H □ □ /250/10+10 | 250 |
20 |
103x398x305 |
70×375 |
|
HYBAFB-35H □ □ /250/20+10 | 250 |
30 |
103x398x365 |
70×375 |
|
HYBAFB-35H □ □ /250/20+20 | 250 |
40 |
103x398x365 |
70×375 |
* Note:Split phase compensation series (built-in 2 sets of capacitors), when equipped with controller, can be only usedJKGHY-Z controller |
three phase compens ation type Secondary current transformer
Name | type | Corresponding selection |
Secondary current transformer |
three phase compensation | Three phase compensation capacitor as master |
split phase (mixed) compensation type | Split phase compensation capacitor as master |
split phase (mixed) compensation type Secondary current transformer
rated voltage, rated capacity, three phase compensation /split phase compensation, application and other parameters need to be provided.
For example: HYBAGB- / 450/30 (20+ 10) 200 units
HYBAGB series, Capacitor rated voltage: 450V, rated capacity: 30kvar, quantity: 200 units