Our enterprise insists all along the standard policy of "product high-quality is base of business survival; client satisfaction could be the staring point and ending of an business; persistent improvement is eternal pursuit of staff" as well as consistent purpose of "reputation first, client first" for Shunt Capacitor For Three Phase, Shunt Capacitor, Hybrid Active Filter, should you have any query or wish to place an initial order please do not hesitate to contact us.
China Wholesale Mikro Power Factor Controller Factories - JKGHYBA580 intelligent combination low voltage reactive power measuring & controller – LASTONE Detail:
Overview
JKGHYBA580 intelligent combination low voltage reactive power measuring&controller device is new type of low voltage reactive power compensation controller that integrates measurement, control and display.
It mainly integrates normal voltmeters, ammeters, power factor meters, reactive power meters, and active power meters in one controller, It can also display three phase compensation current and capacitor switching status display. This product adopts RS485 communication method, which can connect up to 20 pieces of HY series combined low voltage power capacitors.
Model and Meaning
| HKG |
HY |
BA |
- |
580-l |
- |
□□ |
| | |
| |
| |
|
| |
|
| |
| 1 |
2 |
3 |
|
4 |
|
5 |
| No. |
Name |
|
| 1 |
Controller type |
|
| 2 |
Enterprise code |
|
| 3 |
Automatic control |
|
| 4 |
Specification |
580:normal type 580-l:special made (equipped with anti-harmonic) |
| 5 |
Procedure category |
|
*Note:JKGHYBA580-l is equipped with HYBAGK
Technical Parameters
Normal working and installation conditions
| Ambient temperature |
-25°C ~ +55°C |
| Relative humidity |
≤ 50% at 40°C ; ≤ 90% at 20°C |
| Altitude |
≤ 2000m |
| Environmental conditions |
no harmful gas and steam, no conductive or explosive dust, no severe mechanical vibration |
| Power condition |
|
Rated voltage 220V±20%; THDvm5%;
Rated frequency 50Hz±5Hz
Performance
| Measurement accuracy |
voltage: ≤ ±0.5%(0.8-1.2Un)/ current: ≤ ±0.5%(0.2-1.2ln)/ active power reactive ≤ ±2%, reactive power: ≤ ±2%, power factor: ≤ ±1% |
| Control quantity |
20 Pieces |
| Compensation method |
three phase compensation or mixed compensation |
| Control method |
RS485 |
| Protective function |
Over-voltage protection, under-voltage protection, under-current protection, over-harmonic protection |
| Standard |
JB/T 9663-2013 |
| Dimension and structure |
Dimension(WxHxD) Mounting dimension(WxH) |
 |
170x170x120 |
160×160 |
Product detail pictures:
Related Product Guide:
Our concentrate on should be to consolidate and enhance the quality and service of present products, meanwhile consistently produce new products to meet unique customers' demands for China Wholesale Mikro Power Factor Controller Factories - JKGHYBA580 intelligent combination low voltage reactive power measuring & controller – LASTONE , The product will supply to all over the world, such as: California, Mozambique, Peru, Each customer's satisfactory is our goal. We are looking for long-term cooperation with each customer. To meet this, we keep up our quality and provide extraordinary customer service. Welcome to our company, we are expecting to cooperate with you.