We take pleasure in a really excellent name amongst our shoppers for our exceptional product or service excellent, competitive rate and also the greatest services for Run Capacitor Furnace Blower Motor, Single Phase Capacitor Run Motor, Var Generator, We also ensure that your choice is going to be crafted with the highest good quality and dependability. Be sure to feel free of charge to contact us for additional information.
China Wholesale Harmonic Filter Reactor Suppliers - Three phase series filter reactor – LASTONE Detail:
Overview
CKSG series three phase series filter reactors are often affected by harmonic current, switching inrush current and operating overvoltage when compensating capacitive reactive power, which will cause capacitor damage and power factor reduction. Install three phase filter reactors to suppress and absorb harmonics, protect capacitors, avoid the effects of harmonic voltage current and impulse voltage current, improve power quality, increase system power factor, and extend capacitor life
Standard:
● GB/T 1094.6-2011
● GB/T 19212.1-2016
Features
● Designed with secondary thermal sensitive temperature protection switch
● Full vacuum dipping process, low noise during operation
● Winding frame is reinforced environmental protection flame retardant plastic
Model and Meaning
| CKSG |
- 
|
-
|
-7%
|
P |
K |
| │ |
│ |
│ |
│ |
│ |
│ |
| 1 |
2 |
3 |
4 |
5 |
6 |
| No. |
Name |
Meaning |
| 1 |
Series code |
Dry air-cooled three phase series filter reactor CKDG: single phase |
| 2 |
Matching Capacitor rated voltage (kV) |
|
| 3 |
Rated capacity of matched capacitor (kvar) |
|
| 4 |
Rated reactance rate XL / Xc (%) |
△ :three phase compensation; Y:split phase compensation |
| 5 |
P: terminal block |
RS485 |
| 6 |
K: with temperature protection switch |
No mark: without temperature protection switch |
Technical Parameters
Normal working and installation conditions
| Ambient temperature |
-25°C~+50°C |
| Relative humidity |
Relative humidity ≤ 50% at 40°C ; ≤ 90% at 20°C |
| Altitude |
≤ 1000m |
| Performance |
|
| Rated voltage of capacitor |
0.4 kV、0.45 kV、0.48 kV、0.525 kV、0.66kV、0.69 kV; |
| Reactance ratio |
Reactance rate 4.5%, 5%, 6%, 7% is used to limit switching inrush current and suppress 5th and above harmonics
|
| Reactance ratio |
Reactance rate 12%, 14%, used to limit closing switching current and suppress 3rd and above harmonics
|
| Withstand voltage level 3.5kV / min |
5kV/min |
| Insulation class |
B, F, H; Noise ≤ 45dBz continuous operation under overload capacity ≤ 1.35ln |
| Dimension and structure |
Product category |
Specification |
Dimension WxDx H(mm) |
Mounting dimensiWxD(mm) |
 |
CKSG 7% copper wire |
5~10 kvar |
210x145x170 |
110×85
|
| 15-25 kvar |
210x155x175 |
110×85
|
| 30-50 kvar |
240x160x215 |
135×110
|
| CKSG 7% Aluminum wire |
5~8 kvar |
210x150x170 |
110×85
|
|
10-15 kvar
|
210x150x170 |
110×85
|
|
20-25 kvar
|
240x155x195 |
135×110
|
|
30-35 kvar
|
240x155x215 |
135×110
|
|
40-50 kvar
|
262x180x215 |
150×110
|
| CKSG 14% copper wire |
25-30 kvar
|
240x160x200 |
135×110
|
| CKSG 14% Aluminum wire |
25-30 kvar
|
270x190x215 |
150×120
|
| CKSG 14% copper wire. Aluminum wire |
40-50 kvar
|
290x190x240 |
180×120
|
Product detail pictures:
Related Product Guide:
It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions regularly. It regards shoppers, success as its very own success. Let us establish prosperous future hand in hand for China Wholesale Harmonic Filter Reactor Suppliers - Three phase series filter reactor – LASTONE , The product will supply to all over the world, such as: Botswana, Boston, Greece, Besides strong technical strength, we also introduce advanced equipment for inspection and conduct strict management. All the staff of our company welcome friends both at home and abroad to come for visits and business on the basis of equality and mutual benefit. If you are interested in any of our items, please feel free to contact us for quotation and product details.