To be the stage of realizing dreams of our employees! To build a happier, far more united and far more specialist team! To reach a mutual profit of our customers, suppliers, the society and ourselves for Shunt Capacitor Compensation, Power Factor Correction Controller, Automatic Power Controller, Should further information be required, please contact us at any time!
China Wholesale Electric Reactor Pricelist - Three phase series filter reactor – LASTONE Detail:
Overview
CKSG series three phase series filter reactors are often affected by harmonic current, switching inrush current and operating overvoltage when compensating capacitive reactive power, which will cause capacitor damage and power factor reduction. Install three phase filter reactors to suppress and absorb harmonics, protect capacitors, avoid the effects of harmonic voltage current and impulse voltage current, improve power quality, increase system power factor, and extend capacitor life
Standard:
● GB/T 1094.6-2011
● GB/T 19212.1-2016
Features
● Designed with secondary thermal sensitive temperature protection switch
● Full vacuum dipping process, low noise during operation
● Winding frame is reinforced environmental protection flame retardant plastic
Model and Meaning
| CKSG |
- 
|
-
|
-7%
|
P |
K |
| │ |
│ |
│ |
│ |
│ |
│ |
| 1 |
2 |
3 |
4 |
5 |
6 |
| No. |
Name |
Meaning |
| 1 |
Series code |
Dry air-cooled three phase series filter reactor CKDG: single phase |
| 2 |
Matching Capacitor rated voltage (kV) |
|
| 3 |
Rated capacity of matched capacitor (kvar) |
|
| 4 |
Rated reactance rate XL / Xc (%) |
△ :three phase compensation; Y:split phase compensation |
| 5 |
P: terminal block |
RS485 |
| 6 |
K: with temperature protection switch |
No mark: without temperature protection switch |
Technical Parameters
Normal working and installation conditions
| Ambient temperature |
-25°C~+50°C |
| Relative humidity |
Relative humidity ≤ 50% at 40°C ; ≤ 90% at 20°C |
| Altitude |
≤ 1000m |
| Performance |
|
| Rated voltage of capacitor |
0.4 kV、0.45 kV、0.48 kV、0.525 kV、0.66kV、0.69 kV; |
| Reactance ratio |
Reactance rate 4.5%, 5%, 6%, 7% is used to limit switching inrush current and suppress 5th and above harmonics
|
| Reactance ratio |
Reactance rate 12%, 14%, used to limit closing switching current and suppress 3rd and above harmonics
|
| Withstand voltage level 3.5kV / min |
5kV/min |
| Insulation class |
B, F, H; Noise ≤ 45dBz continuous operation under overload capacity ≤ 1.35ln |
| Dimension and structure |
Product category |
Specification |
Dimension WxDx H(mm) |
Mounting dimensiWxD(mm) |
 |
CKSG 7% copper wire |
5~10 kvar |
210x145x170 |
110×85
|
| 15-25 kvar |
210x155x175 |
110×85
|
| 30-50 kvar |
240x160x215 |
135×110
|
| CKSG 7% Aluminum wire |
5~8 kvar |
210x150x170 |
110×85
|
|
10-15 kvar
|
210x150x170 |
110×85
|
|
20-25 kvar
|
240x155x195 |
135×110
|
|
30-35 kvar
|
240x155x215 |
135×110
|
|
40-50 kvar
|
262x180x215 |
150×110
|
| CKSG 14% copper wire |
25-30 kvar
|
240x160x200 |
135×110
|
| CKSG 14% Aluminum wire |
25-30 kvar
|
270x190x215 |
150×120
|
| CKSG 14% copper wire. Aluminum wire |
40-50 kvar
|
290x190x240 |
180×120
|
Product detail pictures:
Related Product Guide:
With our rich experience and considerate services, we have been recognized as a reliable supplier for many international buyers for China Wholesale Electric Reactor Pricelist - Three phase series filter reactor – LASTONE , The product will supply to all over the world, such as: Algeria, Israel, Seattle, With the effort to keep pace with world's trend, we'll always endeavor to meet customers' demands. If you want develop any other new items, we can customize them to suit your needs. If you feel interest in any of our products and solutions or want develop new merchandise, you should feel free to contact us. We are looking forward to forming successful business relationship with customers all over the world.