We have now our possess revenue group, design staff, technical crew, QC team and package group. We now have strict excellent regulate procedures for each process. Also, all of our workers are experienced in printing subject for Apf Active Power Filter Reactor, Compressor Run Capacitor, Power Quality, Should you be fascinated in any of our products and services, remember to do not hesitate to make contact with us. We're ready to reply you inside of 24 several hours soon after receipt of one's ask for and also to develop mutual un-limited advantages and organization in around potential.
China Wholesale Detuned Reactor Pricelist - Three phase series filter reactor – LASTONE Detail:
Overview
CKSG series three phase series filter reactors are often affected by harmonic current, switching inrush current and operating overvoltage when compensating capacitive reactive power, which will cause capacitor damage and power factor reduction. Install three phase filter reactors to suppress and absorb harmonics, protect capacitors, avoid the effects of harmonic voltage current and impulse voltage current, improve power quality, increase system power factor, and extend capacitor life
Standard:
● GB/T 1094.6-2011
● GB/T 19212.1-2016
Features
● Designed with secondary thermal sensitive temperature protection switch
● Full vacuum dipping process, low noise during operation
● Winding frame is reinforced environmental protection flame retardant plastic
Model and Meaning
| CKSG |
- 
|
-
|
-7%
|
P |
K |
| │ |
│ |
│ |
│ |
│ |
│ |
| 1 |
2 |
3 |
4 |
5 |
6 |
| No. |
Name |
Meaning |
| 1 |
Series code |
Dry air-cooled three phase series filter reactor CKDG: single phase |
| 2 |
Matching Capacitor rated voltage (kV) |
|
| 3 |
Rated capacity of matched capacitor (kvar) |
|
| 4 |
Rated reactance rate XL / Xc (%) |
△ :three phase compensation; Y:split phase compensation |
| 5 |
P: terminal block |
RS485 |
| 6 |
K: with temperature protection switch |
No mark: without temperature protection switch |
Technical Parameters
Normal working and installation conditions
| Ambient temperature |
-25°C~+50°C |
| Relative humidity |
Relative humidity ≤ 50% at 40°C ; ≤ 90% at 20°C |
| Altitude |
≤ 1000m |
| Performance |
|
| Rated voltage of capacitor |
0.4 kV、0.45 kV、0.48 kV、0.525 kV、0.66kV、0.69 kV; |
| Reactance ratio |
Reactance rate 4.5%, 5%, 6%, 7% is used to limit switching inrush current and suppress 5th and above harmonics
|
| Reactance ratio |
Reactance rate 12%, 14%, used to limit closing switching current and suppress 3rd and above harmonics
|
| Withstand voltage level 3.5kV / min |
5kV/min |
| Insulation class |
B, F, H; Noise ≤ 45dBz continuous operation under overload capacity ≤ 1.35ln |
| Dimension and structure |
Product category |
Specification |
Dimension WxDx H(mm) |
Mounting dimensiWxD(mm) |
 |
CKSG 7% copper wire |
5~10 kvar |
210x145x170 |
110×85
|
| 15-25 kvar |
210x155x175 |
110×85
|
| 30-50 kvar |
240x160x215 |
135×110
|
| CKSG 7% Aluminum wire |
5~8 kvar |
210x150x170 |
110×85
|
|
10-15 kvar
|
210x150x170 |
110×85
|
|
20-25 kvar
|
240x155x195 |
135×110
|
|
30-35 kvar
|
240x155x215 |
135×110
|
|
40-50 kvar
|
262x180x215 |
150×110
|
| CKSG 14% copper wire |
25-30 kvar
|
240x160x200 |
135×110
|
| CKSG 14% Aluminum wire |
25-30 kvar
|
270x190x215 |
150×120
|
| CKSG 14% copper wire. Aluminum wire |
40-50 kvar
|
290x190x240 |
180×120
|
Product detail pictures:
Related Product Guide:
Gaining customer satisfaction is our company's aim forever. We will make great efforts to develop new and top-quality products, meet your special requirements and provide you with pre-sale, on-sale and after-sale services for China Wholesale Detuned Reactor Pricelist - Three phase series filter reactor – LASTONE , The product will supply to all over the world, such as: Tunisia, Iran, Belgium, With more and more Chinese products around the world, our international business is developing rapidly and economic indicators big increase year by year. We have enough confidence to offer you both better products and service, because we are more and more powerful, professional and experience in domestic and international.